
Solar PanelsModel LR5-54HTH-435W
LONGi Hi-MO X6 Explorer LR5-54HTH 435W
Discover LONGi Hi-MO X6 Explorer LR5-54HTH 435W solar panel with high efficiency and 435W power output for optimal energy solutions.
- Maximum Power (Pmax): 435W
- Open Circuit Voltage (Voc): 39.33V
Choose the Maximum Power (Pmax)
What sets the LR5-54HTH-435W apart from the other 4 models in the family: Maximum Power (Pmax) 435W; Open Circuit Voltage (Voc) 39.33V; Short Circuit Current (Isc) 14.22A; Voltage at Maximum Power (Vmpp) 32.84V; Current at Maximum Power (Impp) 13.17A; Module Efficiency 22.3%.
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: AED 105
- 12-year warranty
LONGi Hi-MO X6 Explorer LR5-54HTH 435W features
Simple design embodies modern style
Better energy generation performance
High-quality module guarantees long-term reliability
About the LONGi Hi-MO X6 Explorer LR5-54HTH 435W
The LONGi Hi-MO X6 Explorer LR5-54HTH 435W is a Hi-MO X6 Explorer solar panel engineered for residential rooftop installations, delivering a maximum power output of 435W at 22.3% module efficiency. Under standard test conditions it produces an open-circuit voltage (Voc) of 39.33V, a short-circuit current (Isc) of 14.22A, a voltage at maximum power (Vmp) of 32.84V and a current at maximum power (Imp) of 13.17A. The panel measures 1722×1134×30mm and weighs 20.8kg, with an Anodized aluminum alloy frame and Single glass, 3.2mm coated tempered glass. It operates across -40°C to +85°C, with a nominal operating cell temperature of 45±2°C, a maximum system voltage of DC1500V (IEC/UL) and a maximum series fuse rating of 25A. It withstands a front-side static load of 5400Pa and a rear-side static load of 2400Pa, with a Pmax temperature coefficient of -0.290%/°C, a Voc coefficient of -0.230%/°C and an Isc coefficient of +0.050%/°C. The Hi-MO X6 Explorer LR5-54HTH 435W is certified by IEC 61215, IEC 61730, UL 61730, ISO9001:2015, ISO14001:2015, ISO45001:2018 and IEC62941 and is backed by a 12-year product warranty and a 30-year performance warranty from LONGi Solar.
Specifications last updated 25 March 2026
LONGi Hi-MO X6 Explorer LR5-54HTH 435W full specifications
Environmental(13)
| Temperature Coefficient of Isc | +0.050%/°C |
|---|---|
| Temperature Coefficient of Voc | -0.230%/°C |
| Temperature Coefficient of Pmax | -0.290%/°C |
| Front Side Maximum Static Loading | 5400Pa |
| Rear Side Maximum Static Loading | 2400Pa |
| Hailstone Test | 25mm Hailstone at the speed of 23m/s |
| Operational Temperature | -40°C to +85°C |
| Power Output Tolerance | 0~3% |
|---|---|
| Maximum System Voltage | DC1500V (IEC/UL) |
| Maximum Series Fuse Rating | 25A |
| Nominal Operating Cell Temperature | 45±2°C |
| Protection Class | Class II |
| Fire Rating | UL Type 1 or 2, IEC Class C |
Electrical(6)
| Maximum Power (Pmax) | 435W |
|---|---|
| Open Circuit Voltage (Voc) | 39.33V |
| Short Circuit Current (Isc) | 14.22A |
| Voltage at Maximum Power (Vmpp) | 32.84V |
| Current at Maximum Power (Impp) | 13.17A |
| Module Efficiency | 22.3% |
Mechanical(4)
| Dimensions (L×W×H) | 1722×1134×30mm |
|---|---|
| Weight | 20.8kg |
| Frame Material | Anodized aluminum alloy frame |
| Glass | Single glass, 3.2mm coated tempered glass |
Certifications(7)
- IEC 61215
- IEC 61730
- UL 61730
- ISO9001:2015
- ISO14001:2015
- ISO45001:2018
- IEC62941
Downloads & support
Frequently Asked Questions
What is the maximum power output and efficiency of the LONGi Hi-MO X6 Explorer LR5-54HTH 435W?
The LONGi Hi-MO X6 Explorer LR5-54HTH 435W has a maximum power output of 435W and a module efficiency of 22.3%.
What are the electrical specifications (Voc, Isc, Vmp, Imp) of the Hi-MO X6 Explorer LR5-54HTH 435W?
The Hi-MO X6 Explorer LR5-54HTH 435W has an open-circuit voltage (Voc) of 39.33V, a short-circuit current (Isc) of 14.22A, a voltage at maximum power (Vmp) of 32.84V and a current at maximum power (Imp) of 13.17A.
What are the physical dimensions and weight of the Hi-MO X6 Explorer LR5-54HTH 435W?
The Hi-MO X6 Explorer LR5-54HTH 435W measures 1722×1134×30mm and weighs 20.8kg.
What static loading can the Hi-MO X6 Explorer LR5-54HTH 435W withstand?
The Hi-MO X6 Explorer LR5-54HTH 435W withstands a front-side maximum static load of 5400Pa and a rear-side maximum static load of 2400Pa.
How does the Hi-MO X6 Explorer LR5-54HTH 435W perform across temperature changes?
The Hi-MO X6 Explorer LR5-54HTH 435W has a Pmax temperature coefficient of -0.290%/°C, a Voc coefficient of -0.230%/°C and an Isc coefficient of +0.050%/°C.
What is the maximum system voltage and fuse rating of the Hi-MO X6 Explorer LR5-54HTH 435W?
The Hi-MO X6 Explorer LR5-54HTH 435W has a maximum system voltage of DC1500V (IEC/UL) and a maximum series fuse rating of 25A.
What certifications does the Hi-MO X6 Explorer LR5-54HTH 435W have?
The Hi-MO X6 Explorer LR5-54HTH 435W is certified by IEC 61215, IEC 61730, UL 61730, ISO9001:2015, ISO14001:2015, ISO45001:2018 and IEC62941, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Hi-MO X6 Explorer LR5-54HTH 435W?
The Hi-MO X6 Explorer LR5-54HTH 435W is backed by a 12-year product warranty and a 30-year performance warranty from LONGi Solar.
What frame and glass does the Hi-MO X6 Explorer LR5-54HTH 435W use?
The Hi-MO X6 Explorer LR5-54HTH 435W uses an Anodized aluminum alloy frame and Single glass, 3.2mm coated tempered glass.
What is the operating temperature range of the Hi-MO X6 Explorer LR5-54HTH 435W?
The Hi-MO X6 Explorer LR5-54HTH 435W operates across -40°C to +85°C, with a nominal operating cell temperature of 45±2°C.

